Optical coherence tomography is routinely used clinically for the detection and management of ocular diseases as well as in research where the studies may involve animals. This routine use requires that the developed automated segmentation methods not only be accurate and reliable, but also be adaptable to meet new requirements. We have previously proposed the use of a graph-theoretic approach for the automated 3-D segmentation of multiple retinal surfaces in volumetric human SD-OCT scans. The method ensures the global optimality of the set of surfaces with respect to a cost function. Cost functions have thus far been typically designed by hand by domain experts. This difficult and time-consuming task significantly impacts the adaptability of these methods to new models. Here, we describe a framework for the automated machine-learning based design of the cost function utilized by this graph-theoretic method. The impact of the learned components on the final segmentation accuracy are statistically assessed in order to tailor the method to specific applications. This adaptability is demonstrated by utilizing the method to segment seven, ten and five retinal surfaces from SD-OCT scans obtained from humans, mice and canines, respectively. The overall unsigned border position errors observed when using the recommended configuration of the graph-theoretic method was 6.45 ± 1.87 μm, 3.35 ± 0.62 μm and 9.75 ± 3.18 μm for the human, mouse and canine set of images, respectively.
Journal article
A combined machine-learning and graph-based framework for the segmentation of retinal surfaces in SD-OCT volumes
Biomedical Optics Express, Vol.4(12), pp.2712-2728
0
12/01/2013
DOI: 10.1364/BOE.4.002712
PMCID: PMC3862166
PMID: 24409375
Abstract
Details
- Title: Subtitle
- A combined machine-learning and graph-based framework for the segmentation of retinal surfaces in SD-OCT volumes
- Creators
- Woojin Jeong - University of IowaElliott H Sohn - University of IowaYoung H Kwon - University of IowaRandy Kardon - University of IowaMona K Garvin - University of IowaBhavna J Antony - University of IowaMichael D Abràmoff - University of IowaMatthew M Harper - University of Iowa
- Resource Type
- Journal article
- Publication Details
- Biomedical Optics Express, Vol.4(12), pp.2712-2728
- Event
- 0
- DOI
- 10.1364/BOE.4.002712
- PMID
- 24409375
- PMCID
- PMC3862166
- ISSN
- 2156-7085
- Copyright
- Copyright: © 2013 OSA
- Grant note
- DOI: 10.13039/100000053, name: National Eye Institute (NEI), award: R01 EY018853, R01 EY019112, R01 EY023279; DOI: 10.13039/100000738, name: U.S. Department of Veterans Affairs (VA), award: 1IK2RX000728
- Language
- English
- Date published
- 12/01/2013
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Electrical and Computer Engineering; Biology; Ophthalmology and Visual Sciences
- Record Identifier
- 9983557221002771
Metrics
94 File views/ downloads
99 Record Views