Abstract
Expanding the Use of Surface Plasmon Resonance (SPR) for Characterizing Nephritic Factors in Patients with C3 Glomerulopathy (C3G): TH-PO576
Journal of the American Society of Nephrology, Vol.35(10S)
10/2024
DOI: 10.1681/ASN.2024dp70jspx
Abstract
Background:
Nephritic factors (Nefs) are convertase-directed autoantibodies present in up to 80% of C3 glomerulopathy patients.1 Despite this prevalence and the associated complement dysregulation, there remains much to be learned about Nef characteristics. Previous work used SPR to show Nefs drive disease by stabilizing the convertase and amplifying complement activity.2 However, this work was unable to characterize patients with Nefs sensitive to regulation by DAF or FH (scenarios evident in our patient population). This deficiency limits our understanding of individual patients and opens the possibility that we are missing populations of Nefs all together. We sought to develop a simple regulator-independent SPR technique that can provide a reproducible half-life of the Nef-convertase interaction.
Methods:
C3b was immobilized to an SPR microfluidic chip at 1200RUs. Several concentrations of FB, FD, and IgG were co-injected onto the C3b ligand to form convertase-IgG complexes. The complex dissociated at 37C for 600 seconds (~6-7 half-lives of reagent convertase), to allow total decay of unbound convertase complexes. Then the sensorgram was normalized to 100RUs. The estimated half-life was calculated as the time at which the sensorgram reached 50RUs remaining. We evaluated nine replicates of one polyclonal Nef-positive IgG test subject and five Nef-negative test subjects.
Results:
Both the Nef-positive and Nef-negative polyclonal IgG show specificity to the convertase, as previously supported.3 The Nef-positive stabilization half-life ranged from 2072 to 2084 seconds with a mean of 2080, while the Nef-negative stabilization half-lives ranged from 464 to 598 seconds. The Nef-positive sample had low variability with a SD of only 4.609, and a SE of 1.537. The estimated half-life was independent of the concentration of FB or FD.
Conclusion:
This data suggests our approach was able to reproducibly provide an estimated half-life for the Nef-convertase complex. Furthermore, it shows distinct kinetics between the Nef-positive and Nef-negative autoantibodies. The assay expands the scope of current Nef evaluation by removing the requirement of complement regulator proteins in the kinetic analysis and provides valuable kinetic information for evaluating complement dysregulation in Nef-positive C3G patients regardless of regulator sensitivity.
Details
- Title: Subtitle
- Expanding the Use of Surface Plasmon Resonance (SPR) for Characterizing Nephritic Factors in Patients with C3 Glomerulopathy (C3G): TH-PO576
- Creators
- Christopher CulekCecelia F. FierceCarla M. Nester
- Resource Type
- Abstract
- Publication Details
- Journal of the American Society of Nephrology, Vol.35(10S)
- Publisher
- AMER SOC NEPHROLOGY; WASHINGTON
- DOI
- 10.1681/ASN.2024dp70jspx
- ISSN
- 1046-6673
- eISSN
- 1533-3450
- Grant note
- NIDDKPrivate Foundation
NIDDK Support, Private Foundation Support
- Language
- English
- Date published
- 10/2024
- Academic Unit
- Nephrology, Dialysis and Transplantation; Internal Medicine; Stead Family Department of Pediatrics
- Record Identifier
- 9984740858802771
Metrics
3 Record Views