Abstract
Poster Abstract #15: MRI Measurement of Whole Spinal Cord Volume at 3T: Reproducibility and Relevance to Multiple Sclerosis
Neurotherapeutics, Vol.5(3), pp.495-495
07/2008
DOI: 10.1016/j.nurt.2008.03.016
Abstract
Determine the reproducibility and clinical relevance of measuring whole spinal cord volume in healthy controls and patients with multiple sclerosis (MS) using 3T MRI.
Spinal cord atrophy may be especially relevant to disability in MS. The advent of 3T MRI brings the potential to assess spinal cord volume more precisely than conventional platforms.
Eight patients with MS and five healthy subjects underwent 3T MRI of the whole spinal cord using axial fast spin-echo T2-weighted images. The upper cervical cord volume was calculated at C2–3. The cord volume was acquired using an edge-finding tool based on local thresholding and was normalized by the craniocaudal extent of the cord.
The whole spinal cord volume in the MS group was 8.2% lower
vs. healthy subjects (
p = 0.13; effect size, Cohen's
d = 0.89). Whole spinal cord volume normalized by number of slices was 5% lower in patients with MS (
p = 0.16;
d = 0.79) and whole spinal cord volume normalized by intracranial volume (ICV) was lower by 4.7% in MS
vs. controls (
p = 0.16;
d = 0.63). Normalizing the whole cord volume with number of slices and ICV showed a 1.5% difference in MS
vs. controls (
p = 0.79;
d = 0.50). Upper cervical spinal cord volume was 7% lower in MS
vs. controls (
p = 0.33;
d = 0.51). The whole cord volume scan–rescan, intrarater, and inter-rater coefficient of variation ranged from 0.5% to 0.7%; those for upper cervical cord cross-sectional volume ranged from 1.3% to 3.8%.
In this pilot study, whole spinal cord volume shows larger effect sizes than upper cervical cord volume in differentiating mildly disabled patients with MS from normal controls. Normalization of spinal cord volume by intracranial volume reduced such effect sizes and therefore may not be desirable. Whole spinal cord volume showed higher reproducibility than measurement of upper cervical cord volume.
Study supported by: National Multiple Sclerosis Society (RG3705A1; RG3798A2); National Institutes of Health (NINDS 1R01NS055083-01).
Details
- Title: Subtitle
- Poster Abstract #15: MRI Measurement of Whole Spinal Cord Volume at 3T: Reproducibility and Relevance to Multiple Sclerosis
- Creators
- Ashish Arora - Brigham and Women's HospitalMohit Neema - Brigham and Women's HospitalJames Stankiewicz - Brigham and Women's HospitalJason G. Guss - Brigham and Women's HospitalRohit Bakshi - Brigham and Women's Hospital
- Resource Type
- Abstract
- Publication Details
- Neurotherapeutics, Vol.5(3), pp.495-495
- DOI
- 10.1016/j.nurt.2008.03.016
- ISSN
- 1933-7213
- eISSN
- 1878-7479
- Publisher
- Elsevier Inc
- Language
- English
- Date published
- 07/2008
- Academic Unit
- Psychiatry
- Record Identifier
- 9984632145402771
Metrics
5 Record Views