SU‐FF‐T‐646: Quality Evaluation of Unflattened Photon Beam Model
Medical Physics, Vol.36(6), pp.2673-2673
06/2009
DOI: 10.1118/1.3182144
Abstract
Purpose: Unflattened external photon beams provide extra high dose rate and greatly reduce the treatment time. The purpose of this project is to verify the feasibility of unflattened photon beam modeling for treatment planning and delivery. Method and Materials: Profiles of a set of square open fields are used to determine parameters of the unflattened beam model for Pinnacle3 TPS. The Gamma‐index is used to evaluate the beam model. Decision maps and gamma‐indices are calculated for planned and measured 20×20 cm2 open and jagged fields in order to assess the dosimetric accuracy. Ten cases of gated IMRT liver cancer treatment plans are used to verify the feasibility of clinically using unflattened beams. Results: All PDD and in‐field cross‐plane profiles pass the 2.4mm/2.4% gamma‐index test for the unflattened beam model (NF) while the flattened beam model (WF) passes at 3mm/3%. The 20×20 cm2 open field and the jagged field pass the 3mm/3% decision map check. The ion chamber measurement and the Pinnacle3 calculated profiles passing the middle of the blocked areas in the jagged field agree very well. All points pass the 2.4mm/2.4% gamma‐index test. The percentage dose differences between the prescribed and delivered dose at the isocenter for ten gated IMRT liver cancer cases are within 3% except for one unflattened case, which is 3.9%. This might be due to the uncertainty in the ion chamber set‐up. Both flattened and unflattened cases pass the 3mm/3% decision map check. The passing rate is 83.15% for the WF case and 93.46% for the NF case in the 3mm/3% check and 93.99% for the WF case and 98.45% for the NF case in the 5mm/5% check. The average time reduction is 60%. Conclusion: Clinically, the unflattened external photon beam can be modeled as well as the flattened beam.
Details
- Title: Subtitle
- SU‐FF‐T‐646: Quality Evaluation of Unflattened Photon Beam Model
- Creators
- Y Huang - University of IowaR Flynn - University of IowaR Siochi - 2University of Iowa Hospitals and Clinics, Iowa City, IAJ Bayouth - University of Iowa
- Resource Type
- Conference proceeding
- Publication Details
- Medical Physics, Vol.36(6), pp.2673-2673
- DOI
- 10.1118/1.3182144
- ISSN
- 0094-2405
- eISSN
- 2473-4209
- Number of pages
- 1
- Date published
- 06/2009
- Academic Unit
- Radiation Oncology
- Record Identifier
- 9984313067702771
Metrics
9 Record Views