Journal article
“2 for 1 Phenomenon” on Implantable Cardioverter Defibrillator Intracardiac Tracing
Pacing and clinical electrophysiology, Vol.39(12), pp.1415-1417
12/2016
DOI: 10.1111/pace.12906
PMID: 27346333
Abstract
“2 for 1 phenomenon” is simultaneous anterograde conduction over the fast and slow pathways of the atrioventricular (AV) nodal pathway, leading to a double ventricular response from each atrial beat. This phenomenon can initiate AV nodal reentrant tachycardia (AVNRT). The unique induction of AVNRT was observed in a patient with an implantable cardioverter defibrillator in our case. Minimal to no retrograde invasion of the slow pathway from the anterogradely conducted fast pathway depolarization is the most accepted explanation.
Details
- Title: Subtitle
- “2 for 1 Phenomenon” on Implantable Cardioverter Defibrillator Intracardiac Tracing
- Creators
- ERIC McCLENDON - University of Mississippi Medical CenterTAKEKI SUZUKI - University of Mississippi Medical CenterTANYANAN TANAWUTTIWAT - University of Mississippi Medical CenterTROY E RHODES - University of Mississippi Medical CenterRONALD D BERGER - Johns Hopkins University
- Resource Type
- Journal article
- Publication Details
- Pacing and clinical electrophysiology, Vol.39(12), pp.1415-1417
- DOI
- 10.1111/pace.12906
- PMID
- 27346333
- ISSN
- 0147-8389
- eISSN
- 1540-8159
- Number of pages
- 3
- Language
- English
- Date published
- 12/2016
- Academic Unit
- Cardiovascular Medicine; Internal Medicine
- Record Identifier
- 9984094213602771
Metrics
16 Record Views