Logo image
IRO Home Research units Researcher Profiles
Sign in
A Biomechanical Study of Hyoid Bone and Laryngeal Movements During Swallowing Comparing the Blom Low Profile Voice Inner Cannula and Passy-Muir One Way Tracheotomy Tube Speaking Valves
Journal article   Peer reviewed

A Biomechanical Study of Hyoid Bone and Laryngeal Movements During Swallowing Comparing the Blom Low Profile Voice Inner Cannula and Passy-Muir One Way Tracheotomy Tube Speaking Valves

Prateek Srinet, Douglas J Van Daele, Stewart I Adam, Morton I Burrell, Ryan Aronberg and Steven B Leder
Dysphagia, Vol.30(6), pp.723-729
12/2015
DOI: 10.1007/s00455-015-9649-7
PMID: 26376918

View Online

Abstract

Aged Aged, 80 and over Biomechanical Phenomena Cannula Deglutition - physiology Deglutition Disorders - physiopathology Deglutition Disorders - rehabilitation Female Follow-Up Studies Humans Hyoid Bone - physiopathology Intubation, Intratracheal - instrumentation Larynx - physiopathology Male Middle Aged Prospective Studies Reproducibility of Results Tracheotomy - methods Voice Quality - physiology