Journal article
A method for placing Heschl gyrus depth electrodes: Technical note
Journal of neurosurgery, Vol.112(6), pp.1301-1307
2010
DOI: 10.3171/2009.7.JNS09404
PMID: 19663547
Abstract
A wide range of devices is used to obtain intracranial electrocorticography recordings in patients with medically refractory epilepsy, including subdural strip and grid electrodes and depth electrodes. Penetrating depth electrodes are required to access some brain regions, and 1 target site that presents a particular technical challenge is the first transverse temporal gyrus, or Heschl gyrus (HG). The HG is located within the supratemporal plane and has an oblique orientation relative to the sagittal and coronal planes. Large and small branches of the middle cerebral artery abut the pial surface of the HG and must be avoided when planning the electrode trajectory. Auditory cortex is located within the HG, and there are functional connections between this dorsal temporal lobe region and medial sites commonly implicated in the pathophysiology of temporal lobe epilepsy. At some surgical centers, depth electrodes are routinely placed within the supratemporal plane, and the HG, in patients who require intracranial electrocorticography monitoring for presumed temporal lobe epilepsy. Information from these recordings is reported to facilitate the identification of seizure patterns in patients with or without auditory auras. To date, only one implantation method has been reported to be safe and effective for placing HG electrodes in a large series of patients undergoing epilepsy surgery. This well-established approach involves inserting the electrodes from a lateral trajectory while using stereoscopic stereotactic angiography to avoid vascular injury. In this report, the authors describe an alternative method for implantation. They use frameless stereotaxy and an oblique insertion trajectory that does not require angiography and allows for the simultaneous placement of subdural grid arrays. Results in 19 patients demonstrate the safety and efficacy of the method.
Details
- Title: Subtitle
- A method for placing Heschl gyrus depth electrodes: Technical note
- Creators
- Chandan G REDDY - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesNader S DAHDALEH - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesGregory ALBERT - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesFangxiang Chen - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesDaniel HANSEN - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesKirill NOURSKI - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesHiroto KAWASAKI - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesHiroyuki OYA - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United StatesMatthew A HOWARD - Department of Neurosurgery, University of Iowa, Iowa City, Iowa, United States
- Resource Type
- Journal article
- Publication Details
- Journal of neurosurgery, Vol.112(6), pp.1301-1307
- DOI
- 10.3171/2009.7.JNS09404
- PMID
- 19663547
- NLM abbreviation
- J Neurosurg
- ISSN
- 0022-3085
- eISSN
- 1933-0693
- Publisher
- American Association of Neurological Surgeons; Charlottesville, VA
- Language
- English
- Date published
- 2010
- Academic Unit
- Neurology; Iowa Neuroscience Institute; Neurosurgery; Otolaryngology
- Record Identifier
- 9984020610402771
Metrics
26 Record Views