Journal article
An articulated ankle external fixation system that can be aligned with the ankle axis
The Iowa orthopaedic journal, Vol.15, pp.197-203
1995
PMCID: PMC2329049
PMID: 7634033
Appears in Diamond Open Access
Abstract
Aligning an articulated ankle external fixator with the ankle axis located using a mechanical axis finder has been shown to preserve normal ankle joint kinematics while the fixed hinge device is attached. However, several problems exist preventing the clinical application of this finding for fractures of the tibial plafond. We initiated a series of studies to resolve these issues. First, the accuracy of the mechanical axis finder in biological systems was quantified by comparing it to that of a computationally derived helical axis. Second, a prototype fixator design was developed in the biomechanics lab to increase the versatility of intraoperative fixator placement. Finally, a radiographic method of locating the ankle axis was developed which is based on talar morphology independent of the fractured tibia. The prototype fixator has been accurately aligned along the ankle axis in cadaveric specimens using this method. Open reduction and internal fixation (ORIF) is the accepted method of treatment for tibial plafond fractures. It holds the advantage of sufficient fracture fixation to permit early joint motion. Good results have been reported using this method, but some authors have reported complication rates up to 50%. The wide surgical approaches required, in conjunction with preexisting soft tissue injury, are thought to significantly increase the risk of soft tissue complications. In response to these problems, many investigators are beginning to utilize external fixation as an alternate treatment modality. One external fixation system which has shown particularly good results is a monolateral cross-ankle articulated fixator (Orthofix SRL., Verona, Italy) which allows motion at the ankle joint as the plafond fracture is healing (Figure 1).
Details
- Title: Subtitle
- An articulated ankle external fixation system that can be aligned with the ankle axis
- Creators
- Daniel C Fitzpatrick - University of Iowa, Department of Orthopaedics, Iowa City, USAWendy S Foels - University of Iowa, Department of Orthopaedics, Iowa City, USAD. R Pedersen - University of Iowa, Department of Orthopaedics, Iowa City, USAJ. L Marsh - University of Iowa, Department of Orthopaedics, Iowa City, USAC. L Saltzman - University of Iowa, Department of Orthopaedics, Iowa City, USAT. D Brown - University of Iowa, Department of Orthopaedics, Iowa City, USA
- Resource Type
- Journal article
- Publication Details
- The Iowa orthopaedic journal, Vol.15, pp.197-203
- Publisher
- Dept. of Orthopaedics, The University of Iowa; United States
- PMID
- 7634033
- PMCID
- PMC2329049
- ISSN
- 1541-5457
- eISSN
- 1555-1377
- Language
- English
- Date published
- 1995
- Academic Unit
- Orthopedics and Rehabilitation
- Record Identifier
- 9984040359502771
Metrics
34 Record Views