Journal article
An earthquake isolation system for steam generators in nuclear power plants
Nuclear engineering and design, Vol.73(3), pp.229-252
12/1982
DOI: 10.1016/0029-5493(82)90001-2
Abstract
This paper describes an experimental/analytical study of the effectiveness of base isolation and damped interaction between a model of a steam generator and its primary housing structure in a nuclear power plant subjected to earthquake ground motion. The design of the test generator model, its connection to the primary structure by yielding elements and the influence of such yielding restrainers on the response of the generator are included. Details of an optimal design problem for selection of the “best” combination of isolation and energy absorption devices are presented and their effectiveness demonstrated.
Details
- Title: Subtitle
- An earthquake isolation system for steam generators in nuclear power plants
- Creators
- M.A Bhatti - University of Iowa, Iowa City, IA 52242, USAV Ciampi - University of Rome, Rome, ItalyJ.M KellyK.S Pister
- Resource Type
- Journal article
- Publication Details
- Nuclear engineering and design, Vol.73(3), pp.229-252
- Publisher
- Elsevier B.V
- DOI
- 10.1016/0029-5493(82)90001-2
- ISSN
- 0029-5493
- eISSN
- 1872-759X
- Language
- English
- Date published
- 12/1982
- Academic Unit
- Civil and Environmental Engineering
- Record Identifier
- 9983991965802771
Metrics