Journal article
Biomechanical risk factors for knee osteoarthritis when using passive and powered ankle-foot prostheses
Clinical biomechanics (Bristol), Vol.29(10), pp.1186-1192
12/2014
DOI: 10.1016/j.clinbiomech.2014.09.005
PMID: 25440576
Abstract
Gait compensations following transtibial amputation negatively affect sound limb loading and increase the risk of knee osteoarthritis. Push-off assistance provided by new powered prostheses may decrease the demands on the sound limb. However, their effects in a young population in the early stages of prosthetic use are still unknown. The purpose of this study was to compare limb loading between 1. passive and powered ankle-foot prostheses, 2. sound and amputated limbs, and 3. individuals with amputations in the relatively early stages of prosthetic use and controls.
Ten young, active individuals with unilateral transtibial amputation and 10 controls underwent biomechanical gait analysis at three speeds. The peak external knee flexor and adductor moments, adductor moment's angular impulse, peak vertical ground reaction force and loading rate were calculated. Repeated measures ANOVAs compared between limbs, prostheses, and groups.
The powered prosthesis did not decrease the sound limb's peak adduction moment or its impulse, but did decrease the external flexor moment, peak vertical force and loading rate as speed increased. The powered prosthesis decreased the loading rate from controls. The sound limb did not display a significantly greater risk for knee osteoarthritis than the intact limb or than controls in either device.
In the early stages of prosthetic use, young individuals with transtibial amputation display few biomechanical risk factors for knee osteoarthritis development. However, a powered ankle-foot prosthesis still offers some benefits and may be used prophylactically to mitigate potential increases of these variables with continued prosthetic use over time.
Details
- Title: Subtitle
- Biomechanical risk factors for knee osteoarthritis when using passive and powered ankle-foot prostheses
- Creators
- Elizabeth Russell Esposito - Center for the Intrepid, Brooke Army Medical Center, Ft. Sam Houston, TX 78234, USA; DoD-VA Extremity Trauma and Amputation Center of Excellence (EACE), USA. Electronic address: erussell.kin@gmail.comJason M Wilken - Center for the Intrepid, Brooke Army Medical Center, Ft. Sam Houston, TX 78234, USA; DoD-VA Extremity Trauma and Amputation Center of Excellence (EACE), USA
- Resource Type
- Journal article
- Publication Details
- Clinical biomechanics (Bristol), Vol.29(10), pp.1186-1192
- Publisher
- England
- DOI
- 10.1016/j.clinbiomech.2014.09.005
- PMID
- 25440576
- ISSN
- 0268-0033
- eISSN
- 1879-1271
- Grant note
- name: Center for Rehabilitation Sciences Research (CRSR); name: Department of Physical Medicine and Rehabilitation; name: Uniformed Services University of Health Sciences; name: U.S. Army Telemedicine & Advanced Technology Research Center (TATRC), award: W81K00-09-P-1129
- Language
- English
- Date published
- 12/2014
- Academic Unit
- Physical Therapy and Rehabilitation Science
- Record Identifier
- 9984047799802771
Metrics
28 Record Views