Journal article
Bone flap elevation for intracranial EEG monitoring: technical note
Journal of neurosurgery, Vol.129(1), pp.182-187
07/2018
DOI: 10.3171/2017.3.JNS163109
PMID: 28946179
Abstract
Intracranial electroencephalography (iEEG) provides invaluable information in determining seizure focus and spread due to its high spatial and temporal resolution, which are not afforded by noninvasive studies. Electrodes of various types (e.g., grid, strip, and depth electrodes) and configurations are often used for optimum coverage of suspected areas of seizure onset and propagation. Given the fixed intracranial volume and added mass effect from placement of cortical electrodes, brain edema and postoperative deficits can occur.The authors describe a simple, inexpensive, and highly effective technique of bone flap replacement using standard titanium plates to expand the intracranial volume and minimize risks of brain compression and intracranial hypertension. Rectangular titanium plates are bent and placed in a way that secures the bone flap in a slightly elevated position relative to the adjacent calvaria during iEEG monitoring. The authors evaluated the degree of bone flap elevation and amount of volume created using this technique in 3 iEEG cases. They then compared these results with the bone flap elevation and volume created using linear titanium plates, a method they had used previously. The use of rectangular plates produced on average 6.6 mm of bone flap elevation, compared with only 1.8 mm of bone flap elevation with the use of linear plates, resulting in a statistically significant 261% increase in bone flap elevation (p ≤ 0.001). The authors suggest that rectangular plates may provide stronger resistance to scalp tension after myocutaneous skin closure compared with the linear plates and that subsidence of the bone flap likely occurred with the use of linear plates. In summary, the described technique utilizing rectangular plates creates significantly increased bone flap elevation compared with a similar method using linear plates, and it may reduce the risk of neurological deficits related to intracranial electrode placement.
Details
- Title: Subtitle
- Bone flap elevation for intracranial EEG monitoring: technical note
- Creators
- Yasunori Nagahama - Departments of 1Neurosurgery andBrian J Dlouhy - Departments of 1Neurosurgery andDaichi Nakagawa - 2Department of Neurosurgery, University of Tokyo, JapanJanina Kamm - 3Neurology, University of Iowa Hospitals and Clinics, Iowa City, Iowa; andDavid Hasan - Departments of 1Neurosurgery andMatthew A Howard III - Departments of 1Neurosurgery andHiroto Kawasaki - Departments of 1Neurosurgery and
- Resource Type
- Journal article
- Publication Details
- Journal of neurosurgery, Vol.129(1), pp.182-187
- DOI
- 10.3171/2017.3.JNS163109
- PMID
- 28946179
- NLM abbreviation
- J Neurosurg
- ISSN
- 0022-3085
- eISSN
- 1933-0693
- Language
- English
- Date published
- 07/2018
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Neurology; Stead Family Department of Pediatrics; Iowa Neuroscience Institute; Neurosurgery; Otolaryngology
- Record Identifier
- 9984020653502771
Metrics
31 Record Views