Changes in intracuff pressure of a cuffed endotracheal tube during surgery for congenital heart disease using cardiopulmonary bypass
Journal article   Open access   Peer reviewed

Changes in intracuff pressure of a cuffed endotracheal tube during surgery for congenital heart disease using cardiopulmonary bypass

Hiromi Kako, Omar Alkhatib, Senthil G. Krishna, Sarah Khan, Aymen Naguib and Joseph D. Tobias
Pediatric anesthesia, Vol.25(7), pp.705-710
07/2015
DOI: 10.1111/pan.12631
PMID: 25735902
url
https://doi.org/10.1111/pan.12631View
Published (Version of record) Open Access

Abstract

Background: With the development of newer polyurethane cuffed endotracheal tubes (cETTs), there has been a shift in clinical practice among pediatric anesthesiologists. Despite improvements in design, excessive inflation of the cuff can still compromise tracheal mucosal perfusion. Several perioperative factors can affect the intracuff pressure (CP), and there is no consensus on safe CP in pediatric patients undergoing repair of congenital cardiac disease (CHD) utilizing cardiopulmonary bypass (CPB). In the current study, the CP was continuously monitored in pediatric patients undergoing surgery for CHD. Methods: After IRB approval, this observational study was conducted on pediatric patients who underwent repair of CHD using CPB with a cETT in place. After anesthetic induction and endotracheal intubation, the cuff was inflated using the air leak technique while maintaining a continuous positive airway pressure of 20 cmH2 O. After inflation, the CP was continuously monitored throughout the procedure. In addition, temperature and mean arterial pressure (MAP) were also recorded. Results: The study included 33 patients who ranged in age from 1 month to 15.3 years. Their weight ranged from 4.0 to 83.6 kg. Six patients were excluded from the analysis due to the need to add or remove air from the cuff, leaving 27 patients for data analysis for cuff pressure over time. The baseline CP at the time of inflation was 16.1 ± 7.6 cmH2 O. With the use of CPB and initiation of hypothermia, when compared to the baseline, the CP decreased by -0.7 ± 5.8 cmH2 O at 35-37°C, -9.1 ± 8.4 cmH2 O at 31-33°C, -7.8 ± 6.2 cmH2 O at 27-29°C, and -11.1 ± 6.0 cmH2 O at <27°C. With rewarming, the CP increased back to the baseline level (-3.5 ± 7.0 cmH2 O). Conclusion: There was a significant decrease in the CP during CPB and associated hypothermia. This may offer some protection for mucosal perfusion during CPB which is usually associated with lower than normal MAP. However, the decrease in the CP may compromise the tracheal seal which may not offer the intended protection for the airway from aspiration.
Pediatrics airway management endotracheal intraoperative monitoring intubation

Details

Metrics

Logo image