Journal article
Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography
Magnetic resonance in medicine, Vol.58(3), pp.636-642
09/2007
DOI: 10.1002/mrm.21285
PMCID: PMC2943874
PMID: 17763351
Abstract
An anthropomorphic airway tree phantom was imaged with both hyperpolarized (HP) 3He MRI using a dynamic projection scan and computed tomography (CT). Airway diameter measurements from the HP 3He MR images obtained using a newly developed model-based algorithm were compared against their corresponding CT values quantified with a well-established method. Of the 45 airway segments that could be evaluated with CT, only 14 airway segments (31%) could be evaluated using HP 3He MRI. No airway segments smaller than approximately 4 mm in diameter and distal to the fourth generation were adequate for analysis in MRI. For the 14 airway segments measured, only two airway segments yielded a non-equivalent comparison between the two imaging modalities, while eight more had inconclusive comparison results, leaving only four airway segments (29%) that satisfied the designed equivalence criteria. Some of the potential problems in airway diameter quantification described in the formulation of the model-based algorithm were observed in this study. These results suggest that dynamic projection HP 3He MRI may have limited utility for measuring airway segment diameters, particularly those of the central airways.
Details
- Title: Subtitle
- Comparison of airway diameter measurements from an anthropomorphic airway tree phantom using hyperpolarized 3He MRI and high-resolution computed tomography
- Creators
- Yang-Sheng Tzeng - Department of Radiology, Brigham and Women's Hospital, and Department of Biomedical Engineering, Boston University, Massachusetts, USAEric HoffmanJanice Cook-GranrothRie MaurerNiral ShahJoey MansourJuerg TschirrenMitchell Albert
- Resource Type
- Journal article
- Publication Details
- Magnetic resonance in medicine, Vol.58(3), pp.636-642
- Publisher
- United States
- DOI
- 10.1002/mrm.21285
- PMID
- 17763351
- PMCID
- PMC2943874
- ISSN
- 0740-3194
- eISSN
- 1522-2594
- Grant note
- R33-EB001689 / NIBIB NIH HHS R33 EB001689-02 / NIBIB NIH HHS R33 EB001689 / NIBIB NIH HHS
- Language
- English
- Date published
- 09/2007
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Radiology; Internal Medicine
- Record Identifier
- 9984051991602771
Metrics
18 Record Views