Journal article
Demonstration of motion-compensated volumetric modulated arc radiotherapy on an MR-linac
Physics and imaging in radiation oncology, Vol.33, 100729
01/2025
DOI: 10.1016/j.phro.2025.100729
PMCID: PMC11880728
PMID: 40046572
Abstract
Intensity-modulated radiotherapy (IMRT) in combination with magnetic resonance imaging (MRI)-guided gated delivery represents the latest development in the treatment of abdominothoracic tumours on MR-linac. In contrast, volumetric-modulated arc therapy (VMAT) is typically used on conventional linacs due to its superior delivery efficiency and speed. Non-inferior VMAT plans were created in a research treatment planning system for eight lung cancer patients previously treated on an MR-linac. VMAT plans were delivered on a moving dosimeter using respiratory multi-leaf collimator (MLC) tracking. VMAT with MLC tracking achieved an average 2%/2 mm local gamma pass rate of 93% relative to planned dose with a delivery efficiency of 83%.
Details
- Title: Subtitle
- Demonstration of motion-compensated volumetric modulated arc radiotherapy on an MR-linac
- Creators
- Pim T.S. Borman - University Medical Center UtrechtPrescilla Uijtewaal - University Medical Center UtrechtJeffrey Snyder - Department of Radiation Oncology, Yale New Haven Health, New Haven, CT, USABryan Allen - University of IowaCaiden K. Atienza - University of IowaPeter Woodhead - University Medical Center UtrechtDaniel E. Hyer - Department of Radiation Oncology, University of Iowa, Iowa City, IA, USABas W. Raaymakers - University Medical Center UtrechtMartin F. Fast - University Medical Center Utrecht
- Resource Type
- Journal article
- Publication Details
- Physics and imaging in radiation oncology, Vol.33, 100729
- DOI
- 10.1016/j.phro.2025.100729
- PMID
- 40046572
- PMCID
- PMC11880728
- NLM abbreviation
- Phys Imaging Radiat Oncol
- ISSN
- 2405-6316
- eISSN
- 2405-6316
- Publisher
- Elsevier B.V
- Grant note
- Elekta ABDutch Research Council (NWO): 20827 IBA Quasar provided the prototype motion platform through ITEA SIGNET: 20052
The authors report research agreements with Elekta AB. UMC Utrecht acknowledges funding by the Dutch Research Council (NWO) through project no. 20827 (ART-PIVOT) . IBA Quasar provided the prototype motion platform through ITEA SIGNET Project Number 20052.
- Language
- English
- Date published
- 01/2025
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Radiation Oncology
- Record Identifier
- 9984790998102771
Metrics
3 Record Views