Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance
Journal of cardiovascular magnetic resonance, Vol.11(1), pp.16-16
2009
DOI: 10.1186/1532-429X-11-16
PMCID: PMC2689210
PMID: 19454023
Abstract
Background
Genetically engineered mouse models of human cardiovascular disease provide an opportunity to understand critical pathophysiological mechanisms. Cardiovascular magnetic resonance (CMR) provides precise reproducible assessment of cardiac structure and function, but, in contrast to echocardiography, requires that the animal be immobilized during image acquisition. General anesthetic regimens yield satisfactory images, but have the potential to significantly perturb cardiac function. The purpose of this study was to assess the effects of general anesthesia and a new deep sedation regimen, respectively, on cardiac function in mice as determined by CMR, and to compare them to results obtained in mildly sedated conscious mice by echocardiography.
Results
In 6 mildly sedated normal conscious mice assessed by echo, heart rate was 615 ± 25 min-1 (mean ± SE) and left ventricular ejection fraction (LVEF) was 0.94 ± 0.01. In the CMR studies of normal mice, heart rate was slightly lower during deep sedation with morphine/midazolam (583 ± 30 min-1), but the difference was not statistically significant. General anesthesia with 1% inhaled isoflurane significantly depressed heart rate (468 ± 7 min-1, p < 0.05 vs. conscious sedation). In 6 additional mice with ischemic LV failure, trends in heart rate were similar, but not statistically significant. In normal mice, deep sedation depressed LVEF (0.79 ± 0.04, p < 0.05 compared to light sedation), but to a significantly lesser extent than general anesthesia (0.60 ± 0.04, p < 0.05 vs. deep sedation).
In mice with ischemic LV failure, ejection fraction measurements were comparable when performed during light sedation, deep sedation, and general anesthesia, respectively. Contrast-to-noise ratios were similar during deep sedation and during general anesthesia, indicating comparable image quality. Left ventricular mass measurements made by CMR during deep sedation were nearly identical to those made during general anesthesia (r2 = 0.99, mean absolute difference < 4%), indicating equivalent quantitative accuracy obtained with the two methods. The imaging procedures were well-tolerated in all mice.
Conclusion
In mice with normal cardiac function, CMR during deep sedation causes significantly less depression of heart rate and ejection fraction than imaging during general anesthesia with isoflurane. In mice with heart failure, the sedation/anesthesia regimen had no clear impact on cardiac function. Deep sedation and general anesthesia produced CMR with comparable image quality and quantitative accuracy.
Details
- Title: Subtitle
- Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance
- Creators
- Christopher J Berry - Division of Cardiovascular Medicine, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USADaniel R Thedens - Department of Radiology, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USAKellyAnn Light-McGroary - Division of Cardiovascular Medicine, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USAJordan D Miller - Division of Cardiovascular Medicine, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USAWilliam Kutschke - Division of Cardiovascular Medicine, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USAKathy A Zimmerman - Iowa City Veterans Affairs Medical Center, Iowa City, Iowa USARobert M Weiss - Division of Cardiovascular Medicine, Roy J. and Lucille A. Carver College of Medicine, University of Iowa, Iowa, USA
- Resource Type
- Journal article
- Publication Details
- Journal of cardiovascular magnetic resonance, Vol.11(1), pp.16-16
- DOI
- 10.1186/1532-429X-11-16
- PMID
- 19454023
- PMCID
- PMC2689210
- NLM abbreviation
- J Cardiovasc Magn Reson
- ISSN
- 1097-6647
- eISSN
- 1532-429X
- Publisher
- BioMed Central
- Language
- English
- Date published
- 2009
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Radiology; Electrical and Computer Engineering; Cardiovascular Medicine; Internal Medicine
- Record Identifier
- 9984094330502771
Metrics
25 Record Views