Journal article
Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system
The journal of advanced prosthodontics, Vol.9(4), pp.265-270
08/01/2017
DOI: 10.4047/jap.2017.9.4.265
PMCID: PMC5582092
PMID: 28874993
Abstract
PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are 171.6 (97.4) mu m for the crown manufactured by the milling system and 149.1 (65.9) and 91.1 (36.4) mu m, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.
Details
- Title: Subtitle
- Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system
- Creators
- Wan-Sun Lee - Kyungpook National UniversityDu-Hyeong Lee - Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, A3DI, 2177 Dalgubuldaero, Daegu 41940, South KoreaKyu-Bok Lee - Kyungpook Natl Univ, Adv Dent Device Dev Inst A3DI, Daegu, South Korea
- Resource Type
- Journal article
- Publication Details
- The journal of advanced prosthodontics, Vol.9(4), pp.265-270
- DOI
- 10.4047/jap.2017.9.4.265
- PMID
- 28874993
- PMCID
- PMC5582092
- NLM abbreviation
- J Adv Prosthodont
- ISSN
- 2005-7806
- eISSN
- 2005-7814
- Publisher
- Korean Acad Prosthodontics
- Number of pages
- 6
- Grant note
- B0101-16-1081 / Institute for Information & Communications Technology Promotion (IITP) - Korea government (MSIP) R0002883 / Ministry of Trade, Industry, and Energy (MOTIE), Korea
- Language
- English
- Date published
- 08/01/2017
- Academic Unit
- Prosthodontics
- Record Identifier
- 9984914014402771
Metrics
2 Record Views