Native hip dislocations require urgent reduction in a setting where adequate sedation and analgesia is essential. We have recently implemented the use of fascia iliaca blocks at our institution for preoperative pain management for patients with proximal femur fractures. In the setting of limited resources, alternate modalities for sedation and analgesia may need to be implemented to obtain a timely reduction for hip dislocations. We present a case report where of the use of a fascia iliaca block along with light sedation to obtain a successful, atraumatic reduction of an anterior dislocation of a native hip joint. While many hip dislocations may require a deeper level of sedation and muscle relaxation for successful reduction, the current report suggests that fascia iliaca blocks provide adequate analgesia for the procedure and may be helpful in the setting of limited resources.
Details
- Title: Subtitle
- Fascia Iliaca Block for Reduction of Anterior Native Hip Dislocation: a Case Report
- Creators
- Christopher West - University of Iowa Department of Orthopaedics and Rehabilitations,Iowa City, IAYatish Ranganath - University of Iowa Department of Anesthesia,Iowa City, IAMichael Willey - University of Iowa Department of Orthopaedics and Rehabilitations,Iowa City, IA
- Resource Type
- Journal article
- Publication Details
- The Iowa orthopaedic journal, Vol.37, pp.19-21
- PMID
- 28852329
- PMCID
- PMC5508297
- NLM abbreviation
- Iowa Orthop J
- ISSN
- 1541-5457
- eISSN
- 1555-1377
- Publisher
- Dept. of Orthopaedics, The University of Iowa; United States
- Language
- English
- Date published
- 2017
- Academic Unit
- Orthopedics and Rehabilitation; Anesthesia; Injury Prevention Research Center
- Record Identifier
- 9984006428702771
Metrics
28 Record Views