Journal article
Field Comparison of Methods for Evaluation of Vapor/Particle Phase Distribution of Ammonia in Livestock Buildings
Journal of Agricultural Safety and Health, Vol.4(2), pp.81-93
1998
DOI: 10.13031/2013.15351
Abstract
Ammonia is a significant respiratory hazard for workers in enclosed livestock buildings. It is hypothesized that ammonia originating from animal wastes is present in both vapor phase and adsorbed onto dust (particulate phase), and that this physical distribution is an important determinant of deposition in the human respiratory system. The goals of this project were: (1) to evaluate the vapor/particle phase distribution of ammonia in enclosed livestock buildings using annular denuders and impingers with prefilters; and (2) to compare the annular denuders air sampling method to traditional active and passive ammonia sampling methods. Ammonia was sampled and analyzed using six methods: annular denuder systems with ion chromatographic (IC) analysis; impingers with pre-filter and IC analysis; impingers without pre-filters with IC analysis; long-term colorimetric tubes; direct reading colorimetric detector tubes; and passive dosimeters. Field studies were conducted in six enclosed swine and poultry buildings during the summer season. Analysis of variance confirmed by individual t-tests indicated that passive dosimeters and long-term colorimetric tubes consistently yielded higher ammonia values than the denuder and impinger methods. Denuder systems were less precise (pooled CV = 0.41) than impingers without pre-filters (pooled CV = 0.16), but more precise than impingers with pre-filters (pooled CV = 0.47). The results of this study indicate that a measurable proportion of ammonia in enclosed livestock buildings is indeed associated with particles, and that annular denuder systems have potential to be used in this environment for evaluation of phase distributions of ammonia. However, the precision and overall collection efficiency of the specific annular denuder evaluated was poor compared to the traditional impinger method, and further work is needed to develop a more suitable denuder system for the relatively higher concentrations of gases and particulates encountered in agricultural environments.
Details
- Title: Subtitle
- Field Comparison of Methods for Evaluation of Vapor/Particle Phase Distribution of Ammonia in Livestock Buildings
- Creators
- S J ReynoldsD Y ChaoP S Thorne - University of Iowa, Civil and Environmental EngineeringP SubramanianP F WaldronM SelimP S WhittenW J Popendorf
- Resource Type
- Journal article
- Publication Details
- Journal of Agricultural Safety and Health, Vol.4(2), pp.81-93
- Publisher
- American Society of Agricultural and Biological Engineers
- DOI
- 10.13031/2013.15351
- ISSN
- 1074-7583
- eISSN
- 1943-7846
- Language
- English
- Date published
- 1998
- Academic Unit
- Occupational and Environmental Health; Civil and Environmental Engineering
- Record Identifier
- 9983997476502771
Metrics
22 Record Views