Journal article
Flow Diversion for Intracranial Aneurysms in Large‐Diameter Vessels: A Subanalysis From the SESSIA Study
Stroke: vascular and interventional neurology, Vol.3(5), e000846
09/2023
DOI: 10.1161/SVIN.123.000846
Appears in UI Libraries Support Open Access
Abstract
Background Flow diverters are now considered first‐line tools for treating intracranial aneurysms. However, few devices are available for patients with large‐diameter vessels (LDVs). Hence, we evaluated the performance of the largest diameter Surpass Streamline for aneurysms in LDVs. Methods We performed a subanalysis of the SESSIA (Safety and Efficacy of the Surpass Streamline for Intracranial Aneurysms) multicenter cohort study of patients treated with Surpass Streamline between 2018 and 2021. Patients in whom a 5‐mm diameter Surpass Streamline was implanted were divided into 2 groups according to vessel diameter at the landing zones (LDV, ≥5.3 mm versus non‐LDV [N‐LDV], <5.3 mm). Efficacy was complete occlusion at final follow‐up. Safety was ischemic/hemorrhagic events and mortality up to 30 days. Results Thirty patients harboring 30 aneurysms were included. Fifteen cases were included per group (LDV versus N‐LDV). Baseline demographics, clinical characteristics, median aneurysm size (LDV, 11 mm versus N‐LDV, 10 mm), and location were similar. Vessel diameters at the proximal (LDV, 5.3 mm versus N‐LDV, 4.2 mm; P <0.001) and distal (5.6 versus 4.0 mm; P <0.001) flow diverter landing zones were different. Procedural characteristics (including balloon‐assisted angioplasty and stenting) were similar. At the final follow‐up (12±6 months), complete occlusion (LDV, 75% versus N‐LDV, 84%; P =0.548), and ischemic/hemorrhagic events (1 per group; P =1.00) were not different. Conclusions The use of large‐diameter flow diverters for treating complex intracranial aneurysms arising in LDVs is technically feasible and safe. Comparative studies evaluating devices suitable for this patient population will provide valuable insights for the best device selection.
Details
- Title: Subtitle
- Flow Diversion for Intracranial Aneurysms in Large‐Diameter Vessels: A Subanalysis From the SESSIA Study
- Creators
- Juan Vivanco-Suarez - University of Iowa Hospitals and ClinicsAaron Rodriguez-Calienes - University of IowaMudassir Farooqui - University of IowaMargarita Rabinovich - Lahey Medical CenterMohamed Abouelleil - Corewell Health Blodgett HospitalDavid J. Altschul - Montefiore Medical CenterChaim Feigen - Montefiore Medical CenterJohanna T. Fifi - Mount Sinai Health SystemStavros Matsoukas - Mount Sinai Health SystemFawaz Al-Mufti - New York Medical CollegeMarco Malaga - University of Iowa Hospitals and ClinicsMilagros Galecio-Castillo - University of IowaAjay K. Wakhloo - Lahey Medical CenterJustin A. Singer - Corewell Health Blodgett HospitalSantiago Ortega-Gutierrez - University of Iowa Hospitals and Clinics
- Resource Type
- Journal article
- Publication Details
- Stroke: vascular and interventional neurology, Vol.3(5), e000846
- DOI
- 10.1161/SVIN.123.000846
- ISSN
- 2694-5746
- eISSN
- 2694-5746
- Publisher
- Wiley
- Language
- English
- Date published
- 09/2023
- Academic Unit
- Neurology; Radiology; Iowa Neuroscience Institute; Neurosurgery
- Record Identifier
- 9984463083502771
Metrics
4 Record Views