Logo image
In-situ measurements of dendrite tip shape selection in a metallic alloy
Journal article   Open access   Peer reviewed

In-situ measurements of dendrite tip shape selection in a metallic alloy

H. Neumann-Heyme, N. Shevchenko, J. Grenzer, K. Eckert, C. Beckermann and S. Eckert
Physical review materials, Vol.6, 063401
06/06/2022
DOI: 10.1103/physrevmaterials.6.063401

View Online

Abstract

The size and shape of the primary dendrite tips determine the principal length scale of the microstructure evolving during solidification of alloys. In−situ x-ray measurements of the tip shape in metals have been unsuccessful so far due to insufficient spatial resolution or high image noise. To overcome these limitations, high-resolution synchrotron radiography and advanced image processing techniques are applied to a thin sample of a solidifying Ga-35wt.%In alloy. Quantitative in−situ measurements are performed of the growth of dendrite tips during the fast initial transient and the subsequent steady growth period, with tip velocities ranging over almost two orders of magnitude. The value of the dendrite tip shape selection parameter is found to be σ∗=0.0768, which suggests an interface energy anisotropy of ɛ4=0.015 for the present Ga-In alloy. The nonaxisymmetric dendrite tip shape amplitude coefficient is measured to be A4≈0.004, which is in excellent agreement with the universal value previously established for dendrites
Physics and Astronomy (miscellaneous) General Materials Science

Details

Metrics

53 Record Views
Logo image