Journal article
Influence of Diamondlike Carbon Coating of Screws on Axial Tightening Force and Stress Distribution on Overdenture Bar Frameworks with Different Fit Levels and Materials
The International journal of oral and maxillofacial implants, Vol.30(5), pp.1019-1027
09/01/2015
DOI: 10.11607/jomi.3730
PMID: 26394336
Abstract
Purpose: The aim of this study was to evaluate the axial tightening force applied by conventional and diamondlike carbon (DLC)-coated screws and to verify, through three-dimensional finite element analysis (FEA), the stress distribution caused by different framework materials and prosthetic screws in overdenture frameworks with different misfit levels. Materials and Methods: The axial tightening force applied by the screw was evaluated by means of a titanium matrix connected to a load cell. Conventional titanium or DLC-coated screws were tightened with a digital torque wrench, and the load values were recorded. The values were applied in an FEA to a bar-clip attachment system connected to two 4.0 x 11-mm external-hexagon titanium implants placed in an anterior edentulous arch. DLC-coated and conventional screws were modeled with their respective axial forces obtained on the experimental evaluation for three bar framework materials (titanium, nickel-chromium, and cobalt-chromium) and three levels of misfit (100, 150, and 200 mu m). Von Mises stresses for prosthetic components and maximum principal stress and microstrains (maximum principal strains) for bone tissue were measured. Results: The mean force applied by the conventional screw was 25.55 N (+/- 1.78); the prosthetic screw coated with a DLC layer applied a mean force of 31.44 N (+/- 2.11), a statistically significant difference. In the FEA, the DLC screw led to higher stresses on the framework; however, the prosthetic screw suffered lower stress. No influence of screw type was seen in the bone tissue. Conclusion: Titanium frameworks reduced the stress transmitted to the bone tissue and the bar framework but had no influence on the screws. Higher misfit values resulted in an increased stress/strain in bone tissue and bar framework, which was not the case for retention screws.
Details
- Title: Subtitle
- Influence of Diamondlike Carbon Coating of Screws on Axial Tightening Force and Stress Distribution on Overdenture Bar Frameworks with Different Fit Levels and Materials
- Creators
- Mateus Bertolini Fernandes dos Santos - Univ Fed Pelotas, Sch Dent, Pelotas, RS, BrazilAtais Bacchi - Merid Fac, Sch Dent, Passo Fundo, RS, BrazilRafael Leonardo Xediek Consani - Univ Estadual Campinas, Piracicaba Dent Sch, Sao Paulo, BrazilLourenco Correr-Sobrinho - Univ Estadual Campinas, Piracicaba Dent Sch, Sao Paulo, Brazil
- Resource Type
- Journal article
- Publication Details
- The International journal of oral and maxillofacial implants, Vol.30(5), pp.1019-1027
- DOI
- 10.11607/jomi.3730
- PMID
- 26394336
- NLM abbreviation
- Int J Oral Maxillofac Implants
- ISSN
- 0882-2786
- eISSN
- 1942-4434
- Publisher
- Quintessence Publishing Co Inc
- Number of pages
- 9
- Grant note
- 2012/19374-5 / FAPESP (Sao Paulo Research Foundation); Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) 12/19374-5 / Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)
- Language
- English
- Date published
- 09/01/2015
- Academic Unit
- Prosthodontics
- Record Identifier
- 9984945919402771
Metrics
2 Record Views