Journal article
Low latency and generalizable dynamic MRI via L+S alternating gradient descent and minimization
Medical physics (Lancaster), Vol.53(11), e70713
10/27/2026
DOI: 10.1002/mp.70713
PMID: 42947508
Abstract
Dynamic MRI reconstruction often requires accurate, fast, and low-latency algorithms that generalize across multiple applications, sampling schemes, and rates, without problem-specific parameter tuning. Existing methods either lack generalizability or require extensive parameter adjustment.
To develop generalizable, low-latency MRI reconstruction algorithms based on low-rank (LR) and low-rank + sparse (L+S) models that are accurate, fast, and require minimal parameter tuning across diverse dynamic MRI settings.
We propose a novel Alternating Gradient Descent and Minimization (AltGDmin) approach for L+S matrix recovery from column-wise undersampled measurements, and extend it to a 3-level hierarchical L+S model for dynamic MRI. A few-shot (FS) learning modification (AGM-L+S-FS) is introduced to enable near low-latency reconstruction with per-frame processing time comparable to or faster than scan time. A simpler LR-only variant is also evaluated.
The proposed algorithms were validated on 6 prospective and 12 retrospective dynamic MRI datasets, covering cardiac, speech, and abdominal applications, with Cartesian, pseudo-radial, radial, and spiral sampling schemes. Experiments demonstrate accurate reconstruction, generalizability across datasets and sampling rates, and low-latency performance. Detailed comparisons with state-of-the-art LR, L+S, low-latency, and unsupervised deep learning methods show superior or comparable performance.
Our AGM-L+S-FS approach provide generalizable, fast, and low-latency MRI reconstruction across multiple dynamic MRI applications and sampling schemes, without the need for problem-specific parameter tuning.
Details
- Title: Subtitle
- Low latency and generalizable dynamic MRI via L+S alternating gradient descent and minimization
- Creators
- Silpa Babu - Iowa State UniversitySajan Goud Lingala - University of IowaNamrata Vaswani - Iowa State University
- Resource Type
- Journal article
- Publication Details
- Medical physics (Lancaster), Vol.53(11), e70713
- DOI
- 10.1002/mp.70713
- PMID
- 42947508
- NLM abbreviation
- Med Phys
- ISSN
- 2473-4209
- eISSN
- 2473-4209
- Publisher
- American Association of Physicists in Medicine
- Grant note
- NSF-2341359 / National Science Foundation R01-HL173483 / National Institutes of Health, National Heart, Lung, and Blood Institute
- Language
- English
- Date published
- 10/27/2026
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Radiology
- Record Identifier
- 9985249172002771
Metrics
2 Record Views