Journal article
Metabolic and microvascular function assessed using near-infrared spectroscopy with vascular occlusion in women: age differences and reliability
Experimental physiology, Vol.108(1), pp.123-134
11/24/2022
DOI: 10.1113/EP090540
PMCID: PMC10103776
PMID: 36420592
Abstract
NEW FINDINGS What is the central question of this study? Can the near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) reliably measure skeletal muscle metabolic and microvascular function in women? What is the main finding and its importance? The NIRS-VOT can be used as a reliable technique for the assessment of skeletal muscle metabolism and microvascular function in women, with reliability being generally greater in younger women. These findings have important implications for the planning and development of future studies employing the NIRS-VOT in women, and provide insights into the effects of age on these parameters in women specifically. ABSTRACTWe investigated the test-retest reliability of, and age-related differences in, markers of skeletal muscle metabolism and microvascular function derived from the near-infrared spectroscopy with vascular occlusion test (NIRS-VOT) in younger women (YW) and middle-aged and older women (MAOW). Seventeen YW (age 23 ± 4 years) and 17 MAOW (age 59 ± 8 years) completed this study. Participants completed identical experimental visits separated by ∼4 weeks during which the NIRS-VOT was used to quantify the occlusion slope, minimum and maximum tissue saturation, ischaemic index, reperfusion magnitude, the reperfusion and 10-s reperfusion slopes (slope 2 and slope 210-s ), time to max tissue saturation, and area under the reperfusion curve using the local tissue oxygen saturation signal. Except for slope 210-s (intraclass correlation coefficient (ICC) = 0.37; coefficient of variation (CV) = 31%), time to max tissue saturation (ICC = 0.21), and ischaemic index (ICC = 0.37) for MAOW, all of the NIRS variables demonstrated good to excellent relative reliability for the YW (ICCs = 0.74-0.86) and the MAOW (ICCs = 0.51-0.87), with CVs of 2-21% and 2-22%, respectively. The occlusion slope was significantly lower, indicating accelerated deoxygenation, while maximum tissue saturation, reperfusion magnitude, and ischaemic index were significantly higher in YW versus MAOW. No other group differences were found. In conclusion, our data support the use of the NIRS-VOT as a simple, reliable, non-invasive technique for the assessment of peripheral skeletal muscle metabolism and microvascular function in women, with the reliability being generally greater in YW versus MAOW. Further, our data suggest that ageing is associated with lower skeletal muscle metabolism and microvascular hyperaemic responsiveness in women.
Details
- Title: Subtitle
- Metabolic and microvascular function assessed using near-infrared spectroscopy with vascular occlusion in women: age differences and reliability
- Creators
- Emily M Rogers - University of IowaNile F Banks - University of IowaNathaniel D M Jenkins - University of Iowa
- Resource Type
- Journal article
- Publication Details
- Experimental physiology, Vol.108(1), pp.123-134
- DOI
- 10.1113/EP090540
- PMID
- 36420592
- PMCID
- PMC10103776
- NLM abbreviation
- Exp Physiol
- ISSN
- 0958-0670
- eISSN
- 1469-445X
- Language
- English
- Date published
- 11/24/2022
- Academic Unit
- Center for Social Science Innovation; Injury Prevention Research Center; Health, Sport, and Human Physiology ; Internal Medicine
- Record Identifier
- 9984319359202771
Metrics
6 Record Views