Modified Cabrol shunt for control of hemorrhage in repair of type A dissection of the aorta
Journal article   Peer reviewed

Modified Cabrol shunt for control of hemorrhage in repair of type A dissection of the aorta

Marc Blum, Anthony Panos, Samuel V Lichtenstein and Tomas A Salerno
The Annals of thoracic surgery, Vol.48(5), pp.709-711
1989
DOI: 10.1016/0003-4975(89)90799-6
PMID: 2818065

View Online

Abstract

A technique of modifying the Cabrol shunt using preserved bovine pericardium and a patch of autologous pericardium to deal with postoperative hemorrhage from an ascending aortic operation is described. A fistula to the right atrium was created for autotransfusion. This simple technique is very useful for dealing with the catastrophic complication of such postoperative hemorrhage.