Journal article
Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study
Circulation (New York, N.Y.), Vol.127(24), pp.2393-2402
2013
DOI: 10.1161/CIRCULATIONAHA.112.001120
PMID: 23694966
Abstract
Background—
Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients.
Methods and Results—
The Pediatric Lead Extractability and Survival Evaluation (PLEASE) is a 24-center international registry. Pediatric and congenital heart disease patients with ICD lead implantations from 2005 to 2010 were eligible. Study subjects comprised 878 ICD patients (44% congenital heart disease). Mean±SD age at implantation was 18.6±9.8 years. Of the 965 total leads, 54% were thin (≤7F), of which 57% were Fidelis, and 23% were coated with expanded polytetrafluoroethylene. There were 139 ICD lead failures (14%) in 132 patients (15%) at a mean lead age of 2.0±1.4 years, causing shocks in 53 patients (40%). Independent predictors of lead failure included younger implantation age and Fidelis leads. Actuarial analysis showed an incremental risk of lead failure with younger age at implantation: <8 years compared with >18 years (P=0.015). The actuarial yearly failure rate was 2.3% for non-Fidelis and 9.1% for Fidelis leads. Extraction was performed on 143 leads (80% thin, 7% expanded polytetrafluoroethylene coated), with lead age as the only independent predictor for advanced extraction techniques. There were 6 major extraction complications (4%) but no procedural mortality.
Conclusions—
This study demonstrates that ICD leads in children and congenital heart disease patients have an age-related suboptimal performance, further compounded by a high failure rate of Fidelis leads. Advanced extraction techniques were common and correlated with older lead age.
Details
- Title: Subtitle
- Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study
- Creators
- Ian H LAW - University of Iowa Children's Hospital, Iowa City, United StatesJoseph ATALLAH - Stollery Children's Hospital, Edmonton, AB, CanadaChristopher C ERICKSON - UNMC/Children's Hospital and Medical Center, Omaha, NE, United StatesMarcin GIERDALSKI - Children's National Medical Center, Washington, DC, United StatesCharles I BERUL - Children's National Medical Center, Washington, DC, United StatesFrank CECCHIN - Children's Hospital Boston, Boston, MA, United StatesAnne M DUBIN - Packard Children's Hospital at Stanford, Palo Alto, CA, United StatesMitchell I COHEN - Phoenix Children's Hospital, Phoenix, AZ, United StatesMartin J LAPAGE - University of Michigan, Ann Arbor, United StatesBryan C CANNON - Mayo Clinic, Rochester, MN, United StatesTerrence U. H CHUN - Seattle Children's Hospital, Seattle, WA, United StatesVicki FREEDENBERG - Children's National Medical Center, Washington, DC, United StatesPediatric and Congenital Electrophysiology Society (PACES)
- Resource Type
- Journal article
- Publication Details
- Circulation (New York, N.Y.), Vol.127(24), pp.2393-2402
- DOI
- 10.1161/CIRCULATIONAHA.112.001120
- PMID
- 23694966
- NLM abbreviation
- Circulation
- ISSN
- 0009-7322
- eISSN
- 1524-4539
- Publisher
- Lippincott Williams & Wilkins
- Language
- English
- Date published
- 2013
- Academic Unit
- Cardiology; Stead Family Department of Pediatrics
- Record Identifier
- 9984093210102771
Metrics
18 Record Views