Journal article
Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions - an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors
Clinical oral investigations, Vol.29(6), 329
06/03/2025
DOI: 10.1007/s00784-025-06400-7
PMID: 40456960
Abstract
To compare the diagnostic performance of three intraoral complementary metal-oxide-semiconductor (CMOS) sensors, one based on direct conversion (CMOS-DC) and two scintillator-dependent sensors, in assessing noncavitated caries-like lesions.
Sixty extracted human caries-free teeth (30 premolars, 30 molars) were selected. A demineralizing solution was used to induce caries-like lesions on the distal surface of 15 premolars (dPM) and the mesial surface of 15 molars (dM), while the remaining teeth were kept sound (sPM, sM). Phantoms were mounted in 4 combinations: dPM-dM, dPM-sM, sPM-dM, and sPM-sM. Standardized radiographs were obtained with one CMOS-DC sensor (XpectVision XVD2530) and two conventional scintillator-dependent CMOS sensors (CMOS-C1: Dexis IXS, and CMOS-C2: Carestream RVG-6200). Three calibrated observers independently assessed the images using a 5-point scale. Observers' agreement, sensitivity, specificity, accuracy and area under the curve (AUC) were analyzed using Kappa, ANOVA, and Tukey test (p ≤ 0.05).
Intra- and interobserver agreements ranged from fair to perfect. Specificity (70.57-83.35), accuracy (64.98-71.10), and AUC (72.63-78.00) showed no statistically significant differences (p > 0.05). The CMOS-DC sensor demonstrated significantly higher sensitivity than CMOS-C2 (p = 0.017). Across all sensors, sensitivity was greater for dPM, with higher AUC values for dPM on CMOS-C1 and CMOS-DC sensors.
The novel CMOS-DC sensor performed comparably to the more commonly used sensors, with slightly superior sensitivity in diagnosing caries-like lesions when those were truly present.
The novel CMOS sensor, based on direct conversion technology, has shown promise in enhancing diagnostic performance and improving clinical outcomes for noncavitated caries lesions.
Details
- Title: Subtitle
- Performance of a novel direct-conversion intraoral sensor on the assessment of caries-like lesions - an ex-vivo comparison with conventional (scintillator-dependent) intraoral sensors
- Creators
- Juliana B Melo da Fonte - University of ConnecticutDaniela Pita de Melo - University of SaskatchewanAna Paula Piovezan Fugolin - Oregon Health & Science UniversitySaulo L Sousa Melo - Oregon Health & Science University
- Resource Type
- Journal article
- Publication Details
- Clinical oral investigations, Vol.29(6), 329
- DOI
- 10.1007/s00784-025-06400-7
- PMID
- 40456960
- NLM abbreviation
- Clin Oral Investig
- ISSN
- 1432-6981
- eISSN
- 1436-3771
- Publisher
- Springer Nature
- Language
- English
- Date published
- 06/03/2025
- Academic Unit
- Radiology; Oral Pathology, Radiology and Medicine
- Record Identifier
- 9985217818902771
Metrics
2 Record Views