Pseudomonas fluorescens bacteremia from blood transfusion
The American journal of medicine, Vol.76(1), pp.62-68
1984
DOI: 10.1016/0002-9343(84)90751-4
PMID: 6419604
Abstract
In October 1980, two units of blood contaminated with Pseudomonas fluorescens caused septic tranfusion reactions in two recipients at a Chicago hospital; one patient died. Both units had been purchased from the same blood center. Investigation at the blood center and at other hospitals it supplied revealed another fatal case of P. fluorescens sepsis that had occurred one year earlier. Despite extensive environmental culturing at the blood center, the source of P. fluorescens was not identified. However, comparison of the interval between collection and administration of contaminated and noncontaminated units indicated that prolonged storage was a risk factor that may have caused clustering of cases in one hospital. Laboratory studies showed that small inocula of P. fluorescens proliferated in refrigerated fresh whole blood and reached 10
6 to 10
7 colonyforming units per milliliter seven days after incubation. These data suggest that prolonged storage of blood may be an important risk factor for the development of transfusion-related sepsis.
Details
- Title: Subtitle
- Pseudomonas fluorescens bacteremia from blood transfusion
- Creators
- Rima F Khabbaz - Atlanta, Georgia USAPaul M Arnow - Chicago, Illinois USAAnita K HighsmithLoreen A HerwaldtTeresa ChouWilliam R JarvisNicholas W LercheJames R Allen
- Resource Type
- Journal article
- Publication Details
- The American journal of medicine, Vol.76(1), pp.62-68
- Publisher
- Elsevier Inc
- DOI
- 10.1016/0002-9343(84)90751-4
- PMID
- 6419604
- ISSN
- 0002-9343
- eISSN
- 1555-7162
- Language
- English
- Date published
- 1984
- Academic Unit
- Infectious Diseases; Epidemiology; Internal Medicine
- Record Identifier
- 9984094583302771
Metrics
22 Record Views