Journal article
Reduction in red blood cell transfusions among preterm infants: results of a randomized trial with an in-line blood gas and chemistry monitor
Pediatrics (Evanston), Vol.115(5), pp.1299-1306
05/2005
DOI: 10.1542/peds.2004-1680
PMCID: PMC2867083
PMID: 15867038
Abstract
Critically ill, extremely premature infants develop anemia because of intensive laboratory blood testing and undergo multiple red blood cell (RBC) transfusions in the early weeks of life. To date, researchers have had only limited success in finding ways to reduce transfusions significantly in this patient population.
To reduce RBC transfusions for these infants by using a point-of-care bedside monitor that returns analyzed blood to the patient.
This was a prospective, 2-center, randomized, open, controlled, clinical trial with a 1:1 assignment of extremely low birth weight infants (weighing 500-1000 g at birth) to control or monitor groups and analysis with the intention-to-treat approach. Predefined RBC transfusion criteria were applied uniformly in the 2 groups.
Clinical treatment of study subjects with an in-line, ex vivo, bedside monitor that withdraws blood through an umbilical artery catheter, analyzes blood gases and sodium, potassium, and hematocrit levels, and returns the sample to the patient.
The total volume and number of RBC transfusions during the first 2 weeks of life and the total volume of blood removed for laboratory testing.
The trial was terminated prematurely when one center's NICU changed its standard method of laboratory testing. In the first 2 weeks of life, there was a nonsignificant 17% lower cumulative RBC transfusion volume in the monitor group (n = 46), compared with the control group (n = 47). However, data from the first week only (the period of greater catheter use) demonstrated a significant 33% lower cumulative RBC transfusion volume in the monitor group. Cumulative phlebotomy loss was approximately 25% less in the monitor group throughout the 2-week study period. There was no difference between groups in neonatal mortality, morbidity, and neurodevelopmental outcome rates at 18 to 24 months. This is the first randomized trial documenting that RBC transfusions administered to neonates can by reduced by decreasing laboratory phlebotomy loss.
As long as an umbilical artery catheter is available for blood sampling with an in-line blood gas and chemistry monitor, significant reductions in neonatal RBC transfusions can be achieved. The patients most likely to benefit from monitor use are the smallest, most critically ill newborns.
Details
- Title: Subtitle
- Reduction in red blood cell transfusions among preterm infants: results of a randomized trial with an in-line blood gas and chemistry monitor
- Creators
- John A Widness - Department of Pediatrics, College of Medicine, University of Iowa, Iowa City, Iowa, USA. john-widness@uiowa.eduAshima MadanLigia A GrindeanuM Bridget ZimmermanDavid K WongDavid K Stevenson
- Resource Type
- Journal article
- Publication Details
- Pediatrics (Evanston), Vol.115(5), pp.1299-1306
- DOI
- 10.1542/peds.2004-1680
- PMID
- 15867038
- PMCID
- PMC2867083
- NLM abbreviation
- Pediatrics
- ISSN
- 0031-4005
- eISSN
- 1098-4275
- Publisher
- United States
- Grant note
- P01 HL46925 / NHLBI NIH HHS M01 RR000059 / NCRR NIH HHS RR00059 / NCRR NIH HHS P01 HL046925 / NHLBI NIH HHS RR00070 / NCRR NIH HHS P01 HL046925-11 / NHLBI NIH HHS M01 RR000070 / NCRR NIH HHS
- Language
- English
- Date published
- 05/2005
- Academic Unit
- Stead Family Department of Pediatrics; Biostatistics
- Record Identifier
- 9983997335302771
Metrics
26 Record Views