Journal article
Repeated Intraocular Pressure Measurement in Awake Lewis Rats Does Not Bias Retinal Ganglion Cell Survival
Current eye research, Vol.35(11), pp.1034-1039
11/2010
DOI: 10.3109/02713683.2010.498654
PMID: 20958192
Abstract
Purpose: The TonoPen applanation tonometry is an established method for intraocular pressure (IOP) measurement. The IOP is one of the main variables affecting retinal ganglion cell (RGC) loss in experimental animal models in ophthalmology and the main risk factor for human glaucoma. In this study, we examined if IOP measurements with the TonoPen itself lead to retinal ganglion cell loss or any other possible retina damages, such as intraocular bleedings or ablation, in Lewis rats.
Methods: Three groups of rats (n = 5 each) were formed. IOP monitoring, using a TonoPen XL, was performed on groups 1 and 3. Animals in groups 1 and 2 received funduscopies before and after one and two weeks of the study, in order to detect possible abnormalities. After two weeks, retinal flatmounts were stained to detect ganglion cells. RGCs were manually counted in eight predefined areas to compare mean RGC densities between groups 1 and 2 (IOP readings vs. no readings), using student t-test.
Results: No significant difference in RGC density between animals that underwent IOP readings and controls could be observed (p = 0.8). As expected, no IOP alterations were monitored in groups 1 and 3 throughout the study. No retinal abnormalities, such as bleeding or retina ablation, were detectable.
Conclusion: We could detect no effects on retinal ganglion cell survival in Lewis rats or any other damages to the retina caused by IOP measurements using a TonoPen XL. This study proposes that repeated applanation tonometry does not affect RGC numbers, one of the main monitored variables in most glaucoma model studies. Therefore, the use of a TonoPen XL for repeated IOP monitoring in Lewis rats can be considered harmless.
Details
- Title: Subtitle
- Repeated Intraocular Pressure Measurement in Awake Lewis Rats Does Not Bias Retinal Ganglion Cell Survival
- Creators
- C. S Cuny - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, GermanyS. C Joachim - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, GermanyO. W Gramlich - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, GermanyP. F Gottschling - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, GermanyN Pfeiffer - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, GermanyF. H Grus - Experimental Ophthalmology, Department of Ophthalmology, University Medical Center, Johannes Gutenberg University, Mainz, Germany
- Resource Type
- Journal article
- Publication Details
- Current eye research, Vol.35(11), pp.1034-1039
- Publisher
- Informa Healthcare
- DOI
- 10.3109/02713683.2010.498654
- PMID
- 20958192
- ISSN
- 0271-3683
- eISSN
- 1460-2202
- Language
- English
- Date published
- 11/2010
- Academic Unit
- Iowa Neuroscience Institute; Neuroscience and Pharmacology; Ophthalmology and Visual Sciences
- Record Identifier
- 9984070968402771
Metrics
22 Record Views