Sensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study
Journal article   Peer reviewed

Sensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study

Alexandra M Arambula, Robin Piper, Gail Murray, Sarah E Mowry, Alejandro Rivas, Maroun Semaan, Nauman F Manzoor, Daniel E Killeen, David C Kelsall, J Eric Lupo, …
Otology & neurotology, Vol.46(6), pp.627-633
07/2025
DOI: 10.1097/MAO.0000000000004502
PMCID: PMC12244962
PMID: 40210225
url
https://www.ncbi.nlm.nih.gov/pmc/articles/12244962View
Open Access

Abstract

Characterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers.OBJECTIVECharacterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers.Retrospective.STUDY DESIGNRetrospective.Multi-institutional, academic and private surgery centers.SETTINGMulti-institutional, academic and private surgery centers.Patients 6 months and older undergoing cochlear implantation.PATIENTSPatients 6 months and older undergoing cochlear implantation.After cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed.INTERVENTIONSAfter cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed.Presence of tip foldovers as determined by TIM recordings and x-rays.MAIN OUTCOME MEASURESPresence of tip foldovers as determined by TIM recordings and x-rays.There were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the "gold standard," TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%.RESULTSThere were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the "gold standard," TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%.These results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.CONCLUSIONSThese results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.
Cochlear implant Electrophysiology Tip foldover TransImpedance Matrix