Logo image
Use of PROMIS for Patients Undergoing Primary Total Shoulder Arthroplasty
Journal article   Open access   Peer reviewed

Use of PROMIS for Patients Undergoing Primary Total Shoulder Arthroplasty

S. Blake Dowdle, Natalie Glass, Chris A. Anthony and Carolyn M. Hettrich
Orthopaedic journal of sports medicine, Vol.5(9), pp.2325967117726044-2325967117726044
09/2017
DOI: 10.1177/2325967117726044
PMCID: PMC5602218
PMID: 28944248
url
https://doi.org/10.1177/2325967117726044View
Published (Version of record) Open Access

Abstract

Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) consists of question banks for health domains through computer adaptive testing (CAT). Hypothesis: For patients with glenohumeral arthritis, (1) there would be high correlation between traditional patient-reported outcome (PRO) measures and the PROMIS upper extremity item bank (PROMIS UE) and PROMIS physical function CAT (PROMIS PF CAT), and (2) PROMIS PF CAT would not demonstrate ceiling effects. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Sixty-one patients with glenohumeral osteoarthritis were included. Each patient completed the American Shoulder and Elbow Surgeons (ASES) assessment form, Marx Shoulder Activity Scale, Short Form-36 physical function scale (SF-36 PF), EuroQol 5 Dimensions (EQ-5D) questionnaire, Western Ontario Osteoarthritis Shoulder (WOOS) index, PROMIS PF CAT, and the PROMIS UE. Correlation was defined as high (>0.7), moderate (0.4-0.6), or weak (0.2-0.3). Significant floor and ceiling effects were present if more than 15% of individuals scored the lowest or highest possible total score on any PRO. Results: The PROMIS PF demonstrated excellent correlation with the SF-36 PF (r = 0.81, P < .0001) and good correlation with the ASES (r = 0.62, P < .0001), EQ-5D (r = 0.64, P < .001), and WOOS index (r = 0.51, P < .01). The PROMIS PF demonstrated low correlation with the Marx scale (r = 0.29, P = .02). The PROMIS UE demonstrated good correlation with the ASES (r = 0.55, P < .0001), SF-36 (r = 0.53, P < .01), EQ-5D (r = 0.48, P < .01), and WOOS (r = 0.34, P <.01), and poor correlation with the Marx scale (r = 0.06, P = .62). There were no ceiling or floor effects observed. The mean number of items administered by the PROMIS PRO was 4. Conclusion: These data suggest that for a patient population with operative shoulder osteoarthritis, PROMIS UE and PROMIS PF CAT may be valid alternative PROs. Additionally, PROMIS PF CAT offers a decreased question burden with no ceiling effects.
Life Sciences & Biomedicine Orthopedics Science & Technology Sport Sciences

Details

Metrics

Logo image