Journal article
Variability of motor cortical excitability using a novel mapping procedure
Journal of neuroscience methods, Vol.214(2), pp.137-143
04/15/2013
DOI: 10.1016/j.jneumeth.2013.01.013
PMCID: PMC3644387
PMID: 23357026
Abstract
► MEP amplitudes were highly reliable using a newly developed technique for examining motor maps. ► MEP amplitudes along an axis ∼45° to the nasion–inion were most reliable. ► Stimulus–response MEP amplitudes showed moderate to high reliability. ► Center of Gravity shifts between sessions were minimal.
The purpose of this study was to assess the reliability of a novel TMS motor cortex mapping procedure. The procedure was designed to take less time and be more clinically useful by delivering fewer MEPS over fewer skull locations. Resting motor evoked potentials (MEPs) were recorded from the first dorsal interosseus muscle of 6 individuals over a fixed 15-point grid. Mean MEP amplitudes, map center of gravity (CoG), and stimulus–response characteristics were assessed before and after a 30-min rest session. As a novel feature, subregions of the map were analyzed for regions of highest test–retest reliability for use as a global measure of cortical excitability. Mean MEP amplitudes between sessions were highly reliable (ICC=0.90–0.92). Reproducibility of MEPs was highest along an axis approximately 45° to the nasion–inion. Stimulus–response MEP amplitudes showed moderate to high reliability (ICC 0.54–0.95). Mean CoG shift between sessions was 2.79±1.2mm. This mapping procedure is reliable and allows efficient assessment of motor cortex excitability.
Details
- Title: Subtitle
- Variability of motor cortical excitability using a novel mapping procedure
- Creators
- Andrew E Littmann - Department of Physical Therapy, Rueckert-Hartman College for Health Professions, Regis University, Denver, CO 80221, United StatesColleen L McHenry - Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, The University of Iowa, 1-252 Medical Education Building, Iowa City, IA 52242-1190, United StatesRichard K Shields - Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, The University of Iowa, 1-252 Medical Education Building, Iowa City, IA 52242-1190, United States
- Resource Type
- Journal article
- Publication Details
- Journal of neuroscience methods, Vol.214(2), pp.137-143
- DOI
- 10.1016/j.jneumeth.2013.01.013
- PMID
- 23357026
- PMCID
- PMC3644387
- NLM abbreviation
- J Neurosci Methods
- ISSN
- 0165-0270
- eISSN
- 1872-678X
- Publisher
- Elsevier B.V
- Language
- English
- Date published
- 04/15/2013
- Academic Unit
- Orthopedics and Rehabilitation; Physical Therapy and Rehabilitation Science
- Record Identifier
- 9984047689802771
Metrics
21 Record Views