Journal article
Wear and Lysis is the Problem in Modular TKA in the Young OA Patient at 10 Years
Clinical orthopaedics and related research, Vol.469(1), pp.41-47
01/01/2011
DOI: 10.1007/s11999-010-1429-y
PMCID: PMC3008910
PMID: 20568028
Abstract
Background Most long-term followup studies of younger patients who underwent TKA include a relatively high percentage of rheumatoid patients, whose function and implant durability may differ from those with osteoarthritis (OA).
Questions/purposes The purpose of this study was to evaluate the minimum 10 year followup of TKA performed in more active patients with OA, using modular tibial components, to determine the durability of that construct. Specifically, we determined (1) survivorship; (2) revision rates; (3) functional scores; and (4) rates of radiographic failure at a minimum 10 year followup.
Methods We retrospectively reviewed 59 patients (67 knees) with OA who underwent primary total knee arthroplasty with posterior cruciate retaining (27%) or posterior cruciate substituting (73%) components which had modular tibial trays. Patients were evaluated clinically for need of revision and Knee Society, SF-36 and WO-MAC scores as well as UCLA and Tegner activity scores. Radiographs were evaluated for loosening and osteolysis. The minimum followup of living patients was 10 years (mean, 12.4 years; range, 10 to 18.4 years). Ten patients (11 knees) died; two patients (2 knees) were lost to followup.
Results Ten patients (11 knees; 16%) had revisions for aseptic loosening and/or osteolysis. Thirty-one patients (65%) were still performing moderate labor or sports activities. The average UCLA score was 5.5 (range, 2-9). No nonrevised knee demonstrated radiographic loosening.
Conclusion Most patients in this active patient population continued to have acceptable function although 16% underwent revision for wear and/or osteolysis. Isolated tibial insert exchange alone was performed in four of the 11 (36%) revised knees. These data should provide comparison for total knee arthroplasties performed in younger patients with newer designs and newer bearing materials.
Details
- Title: Subtitle
- Wear and Lysis is the Problem in Modular TKA in the Young OA Patient at 10 Years
- Creators
- Andrew N. Odland - University of IowaJohn J. Callaghan - University of IowaSteve S. Liu - University of IowaChristopher W. Wells - University of Iowa
- Resource Type
- Journal article
- Publication Details
- Clinical orthopaedics and related research, Vol.469(1), pp.41-47
- Publisher
- Springer Nature
- DOI
- 10.1007/s11999-010-1429-y
- PMID
- 20568028
- PMCID
- PMC3008910
- ISSN
- 0009-921X
- eISSN
- 1528-1132
- Number of pages
- 7
- Language
- English
- Date published
- 01/01/2011
- Academic Unit
- Roy J. Carver Department of Biomedical Engineering; Orthopedics and Rehabilitation
- Record Identifier
- 9984622057602771
Metrics
4 Record Views