Journal article
Measurement of Regional Specific Lung Volume Change Using Respiratory-Gated PET of Inhaled N-13-Nitrogen
The Journal of nuclear medicine (1978), Vol.51(4), pp.646-653
04/01/2010
DOI: 10.2967/jnumed.109.067926
PMCID: PMC3177560
PMID: 20237036
Abstract
Regional specific lung volume change (sVol), defined as the regional tidal volume divided by the regional end-expiratory gas volume, is a key variable in lung mechanics and in the pathogenesis of ventilator-induced lung injury. Despite the usefulness of PET to study regional lung function, there is no established method to assess sVol with PET. We present a method to measure sVol from respiratory-gated PET images of inhaled 13N-nitrogen ((NN)-N-13), validate the method against regional specific ventilation (s(V) over dot), and study the effect of region-of-interest (ROI) volume and orientation on the sVol-s(V) over dot relationship. Methods: Four supine sheep were mechanically ventilated (tidal volume V-T = 8 mL/kg, respiratory rate adjusted to normocapnia) at low (n = 2, positive end-expiratory pressure = 0) and high (n = 2, positive end-expiratory pressure adjusted to achieve a plateau pressure of 30 cm H2O) lung volumes. Respiratory-gated PET scans were obtained after inhaled (NN)-N-13 equilibration both at baseline and after a period of mechanical ventilation. We calculated sVol from (NN)-N-13-derived regional fractional gas content at end-inspiration (F-EI) and end-expiration (FEE) using the formula sVol 5 (F-EI - F-EE)/(F-EE[1 - F-EI]). s(V) over dot was computed as the inverse of the subsequent (NN)-N-13 washout curve time constant. ROIs were defined by dividing the lung field with equally spaced coronal, sagittal, and transverse planes, perpendicular to the ventrodorsal, laterolateral, and cephalocaudal axes, respectively. Results: sVol-s(V) over dot linear regressions for ROIs based on the ventrodorsal axis yielded the highest R-2 (range, 0.71-0.92 for mean ROI volumes from 7 to 162 mL), the cephalocaudal axis the next highest (R-2 = 0.77-0.88 for mean ROI volumes from 38 to 162 mL), and the laterolateral axis the lowest (R-2 = 0.65-0.83 for mean ROI volumes from 8 to 162 mL). ROIs based on the ventrodorsal axis yielded lower standard errors of estimates of sVol from s(V) over dot than those based on the laterolateral axis or the cephalocaudal axis. Conclusion: sVol can be computed with PET using the proposed method and is highly correlated with s(V) over dot. Errors in sVol are smaller for larger ROIs and for orientations based on the ventrodorsal axis.
Details
- Title: Subtitle
- Measurement of Regional Specific Lung Volume Change Using Respiratory-Gated PET of Inhaled N-13-Nitrogen
- Creators
- Tyler J. Wellman - Boston UniversityTilo Winkler - Massachusetts General HospitalEduardo L. V. Costa - Harvard UniversityGuido Musch - Harvard UniversityR. Scott Harris - Massachusetts General HospitalJose G. Venegas - Harvard UniversityMarcos F. Vidal Melo - Harvard University
- Resource Type
- Journal article
- Publication Details
- The Journal of nuclear medicine (1978), Vol.51(4), pp.646-653
- DOI
- 10.2967/jnumed.109.067926
- PMID
- 20237036
- PMCID
- PMC3177560
- NLM abbreviation
- J Nucl Med
- ISSN
- 0161-5505
- eISSN
- 1535-5667
- Publisher
- Soc Nuclear Medicine Inc
- Number of pages
- 8
- Grant note
- 5R01-HL086827; R01 HL086717; R01 HL086827-04; R01 HL086827 / NHLBI NIH HHS; United States Department of Health & Human Services; National Institutes of Health (NIH) - USA; NIH National Heart Lung & Blood Institute (NHLBI) R01HL086717 / NATIONAL HEART, LUNG, AND BLOOD INSTITUTE; United States Department of Health & Human Services; National Institutes of Health (NIH) - USA; NIH National Heart Lung & Blood Institute (NHLBI)
- Language
- English
- Date published
- 04/01/2010
- Academic Unit
- Anesthesia
- Record Identifier
- 9985141863002771
Metrics
1 Record Views